Frost Brochure Issue 03 - Catalog - Page 61
Visit
frostdrainage.com
Call
01420 555572
Final Steps:
Once the concrete has set, remove
spacer bars.
Fit gratings.
Clean channels and gratings with
water and an appropriate cleaning
agent to prevent contamination of
the channel while cleaning do not use
scouring pads containing metal or
wire wool.
Note: Load class ratings are based on
channels set in concrete class C30/37,
fully supporting the grating seat.
For lower load ratings or alternative
concretes, consult a structural
engineer.
Additional Notes for Speci昀椀c
Channel Types
Drainage Channel Pro昀椀le SVF
(Vinyl or Flexible Sheet Material)
•
•
Dress the vinyl into the channel
and seal as per the 昀氀ooring
manufacturer’s guidelines.
Fit clamping frames and gratings
as supplied.
For further assistance or technical
queries, please contact our Technical
Services Department.
61